Target Audience: Electrical Engineers, RF Engineers, Power Electronics Engineers
Reading Time: 10 Minutes
Introduction
Modern products combine power electronics, antennas, sensors, communication radios, high-speed interfaces, cables, motors and wireless systems within increasingly compact spaces. These components can generate or respond to electromagnetic energy, creating the risk of electromagnetic interference (EMI). A switching converter may disturb a nearby sensor; a cable harness may carry unwanted common-mode current; a transmitter antenna may desensitize a receiver; or an external electromagnetic field may disrupt an electronic control unit.
Electromagnetic compatibility (EMC) is the ability of equipment to operate as intended in its electromagnetic environment without introducing unacceptable interference to other equipment. EMI describes the unwanted disturbance itself, while EMC engineering addresses both emissions from a system and its susceptibility or immunity to external disturbances. These concerns extend far beyond antennas: they affect printed circuit boards (PCBs), cable harnesses, enclosures, electric power systems, vehicles, aircraft, industrial machinery, medical electronics and communication infrastructure.
Physical EMC testing remains essential for design verification and regulatory compliance. However, relying only on late-stage testing can make it difficult to identify the exact coupling path or correct a design without costly rework. Computational electromagnetic simulation provides a complementary way to investigate fields, currents, cable interactions, shielding and test-environment effects earlier in development. Altair FEKO supports EMC analyses including radiated emissions and immunity, cable coupling, shielding effectiveness, HIRF, EMP, lightning effects, and reverberation or anechoic-chamber simulation.

Key EMI/EMC Engineering Challenges
1. Identifying Unwanted Radiation and Coupling Paths
Electronic systems rarely operate as isolated components. High-speed circuits, switching power supplies, clock lines, connectors, chassis seams and cable harnesses can contribute to unwanted electromagnetic emissions. A cable intended only to carry signals or power may also behave as an unintended radiator when common-mode currents flow along it. Nearby cables, antennas or electronic modules can then pick up the field and experience induced voltages or currents.
The main difficulty is finding which source, geometry or interconnection creates the dominant coupling path. FEKO can model relevant conductors, cables, antennas and surrounding structures to evaluate radiated fields and electromagnetic coupling. Engineers can compare cable routes, separation distances, grounding assumptions and component locations to understand which design changes are likely to reduce interference. This helps prioritize physical investigations instead of relying only on trial-and-error fixes.
2. Assessing Radiated Emissions and Immunity
Radiated – emissions testing evaluates electromagnetic energy emitted by equipment, while radiated-immunity testing investigates how equipment responds when exposed to an external field. In a real product, emissions and immunity depend on more than the circuit board alone: enclosure geometry, cable routing, apertures, seams, mounting structures and nearby conductive parts can change current distributions and field levels.
Virtual analysis can help engineers examine how an electronic unit or larger platform interacts with incident fields and how its cables or structures radiate. FEKO can represent the device under test (DUT), relevant interconnections and electromagnetic test setup to study field distribution and coupling. For aerospace systems, this can support investigation of high-intensity radiated fields (HIRF); for transient scenarios, time-domain analysis can help assess electromagnetic-pulse (EMP) and lightning-related effects. Simulation should be aligned with the intended test configuration: operating frequency, polarization, field strength, equipment geometry, cable termination and boundary conditions can all influence the result.

3. Evaluating Shielding Effectiveness and Enclosure Design
Metal enclosures, conductive coatings, gaskets and shielded cables are commonly used to limit electromagnetic emissions or protect sensitive electronics. Their performance can be reduced by seams, ventilation slots, connector openings, poorly bonded joints or cable-entry points. A shield that performs well in a simplified component test may behave differently once integrated into the complete assembly.
Electromagnetic simulation can reveal where fields penetrate an enclosure, where surface currents concentrate and which openings or interfaces may dominate leakage. FEKO can be used to study shielding effectiveness and coupling between external fields and internal structures, helping compare aperture dimensions, bonding arrangements, shield placement and cable routing. These investigations can guide targeted physical tests and reduce enclosure iterations.
4. Managing Cable-Harness and Co-Site Interference
Vehicles, aircraft, ships, industrial equipment and communication systems often contain multiple electronic units and radio systems operating close together. Power cables, sensor wiring, data lines and RF feeders may share limited routing space. Energy can couple from one cable to another, from an antenna into a harness, or from a harness into a nearby receiver. The result may be sensor errors, degraded receiver sensitivity, false triggering or unexpected emissions.
FEKO includes specialized cable-modelling and coupling capabilities for analysing cable-to-cable and cable-to-device interactions. Engineers can investigate harness paths, shielding, separation, antenna placement and equipment interfaces before the complete system is built. For co-located transmitters and receivers, electromagnetic coupling analysis can help identify problematic antenna locations or isolation requirements.

5. Reproducing Anechoic-Chamber Conditions Virtually
Anechoic chambers are designed to minimize reflections so antennas and electronic systems can be evaluated in a controlled electromagnetic environment. Absorber-lined walls, a defined test volume, measurement antennas, cable routing and the position of the device under test all influence measurements. At high frequencies, small differences in placement or nearby objects can affect measured fields and radiation patterns.
A virtual chamber model can help engineers study the electromagnetic behaviour of the test setup before a physical campaign. Depending on the objective, the model may include chamber geometry, absorbing materials, measurement antenna, device under test and relevant support structures. FEKO supports anechoic-chamber simulation and can be used to investigate field distribution and interactions between the test object and its environment.
This approach can support questions such as: Is the test volume sufficiently uniform for the intended evaluation? Could reflections from a fixture or support structure influence the result? How does DUT orientation affect the field or measured response? Are nearby cables or metal objects introducing unintended coupling? Virtual analysis helps assess these factors, compare setup options and improve confidence in the planned measurement.
A virtual chamber is not automatically a certified chamber model, and simulation does not replace chamber calibration, site validation or prescribed measurements. Accuracy depends on material properties, boundary conditions, antenna models and a realistic representation of the setup. The strongest workflow uses simulation to prepare and interpret physical testing.

What Can Be Investigated Virtually?
- Radiated emissions: Identify field distributions and likely radiation paths from equipment, cables and structures.
- Radiated immunity: Assess how incident electromagnetic fields couple into a device, harness or platform.
- Cable coupling: Estimate interactions between cable harnesses, antennas and nearby electronic structures.
- Shielding effectiveness: Comparing enclosure, aperture, bonding and shielding concepts.
- Antenna-to-system interaction: Investigate coupling between radio systems and other platform electronics.
- HIRF, EMP and lightning-related effects: Evaluate relevant field or transient coupling scenarios within model assumptions.
- Anechoic and reverberation chamber studies: Analyse electromagnetic behaviour of a test environment and its interaction with the DUT.
Conclusion
As electronic systems become more connected and densely integrated, EMI/EMC risks increasingly emerge from interactions among circuits, cables, enclosures, antennas and the surrounding platform. Identifying these interactions only during final testing can lead to costly redesign and repeated test cycles. Virtual electromagnetic analysis helps engineers investigate radiation paths, cable coupling, shielding effectiveness, immunity and the influence of anechoic-chamber test environments earlier in development.
Altair FEKO provides electromagnetic simulation capabilities for EMC-related investigations, including cable coupling, radiated emissions and immunity, shielding, HIRF, EMP, lightning effects and chamber simulations. When combined with physical measurements and applicable compliance procedures, these capabilities help teams make informed design decisions, improve test preparation and develop more robust electronic and electrical systems.
Connect with us to know more!